The bends was worked out over roughly three centuries, by miners, bridge builders, physiologists, navies and dive-table makers. It began with a snake in a vacuum and ended with the computer on your wrist.
This article covers history and names. For symptoms and what to do after a dive, read our guide to decompression sickness and decompression illness.
Words people use for the same illness
| Term | Plain meaning | Who uses it |
|---|---|---|
| Decompression sickness (DCS) | Illness caused by inert gas, mostly nitrogen, coming out of solution as bubbles in the tissues and bloodstream (DAN glossary). | Dive doctors, DAN, training agencies |
| Decompression illness (DCI) | The broad term that covers both DCS and arterial gas embolism. | Hyperbaric doctors, DAN, researchers |
| Arterial gas embolism (AGE) | Gas bubbles in the arteries, a related condition rather than a type of DCS. | Dive and hyperbaric medicine |
| The bends | The old nickname for DCS. | Divers and the public |
| Caisson disease | The 1870s name for the same illness in compressed-air construction workers. | Historians and older medical writing |
| Cason's disease | Sometimes misspelt as Cason's disease; not a separate condition. | Not a medical term |
What does caisson mean?
A caisson is a box or chamber filled with compressed air so that workers can dig a bridge pier or tunnel foundation below the water. Acott's history notes that caisse is the French word for box, and credits a Frenchman, Triger, with constructing the first caisson in 1841. His caisson was sunk to 20 metres to dig a coal mine at Chalonnes in France.
Triger also recorded the first two cases of decompression sickness, in two miners who came out with sharp pain in an arm, a knee and a shoulder.
Where the name caisson disease came from
Acott records that the Eads Bridge at St Louis employed 352 compressed-air workers in 1871. Thirty were seriously injured and 12 died.
Two years later the Brooklyn Bridge project employed about 600 workers in caissons reaching 78.5 feet (23.8 metres). Its physician, Dr Andrew Smith, described 110 serious cases. Acott credits Smith as the first to use the term caisson disease, and Smith's 1873 book is titled The effects of high atmospheric pressure, including the caisson disease.
The nickname arrived on the same project. In Acott's account, affected workers walked with a stoop that resembled the Grecian bend, a posture then fashionable among women. Doing the bend became being bent, and then the bends.
Before the bridges: bubbles in a viper
The first recorded description of what we now call decompression sickness is older than the caisson. In 1670 Robert Boyle placed a viper in a vacuum and saw bubbles form in living tissue. Acott notes this went unappreciated for nearly 200 years.
Paul Bert shows the cause (1878)
The French physiologist Paul Bert published La Pression Barométrique in 1878. According to Acott, he demonstrated that nitrogen bubbles cause decompression sickness, recognised that bubbles can exist without symptoms, and recommended recompression and oxygen for treatment.
Haldane, the Admiralty and the goats (1905 to 1908)
In 1905 the British Admiralty appointed John Scott Haldane to develop safe decompression procedures. Haldane later used data from Leonard Hill and Greenwood, who in 1906 suggested a uniform decompression of 20 minutes per atmosphere.
Haldane tested decompression strategies on goats. He fitted the goat data with five theoretical compartments with half-times of 5, 10, 20, 40 and 75 minutes, and assumed tissues could withstand up to a 2 to 1 pressure ratio on the way up without harm.
In 1908 Haldane, Arthur Boycott and Guybon Damant published The Prevention of Compressed Air Illness. It recommended staged decompression. The Royal Navy accepted the tables for dives to 34 fathoms (204 feet, 61.2 metres).
The US Navy tables and the first no-stop tables
The US Navy Diving Tables were first published in 1915 as a version of Haldane's tables, modified by French and Stillson, with a maximum depth of 300 feet (90 metres). Acott records that in 1937 Albert Behnke introduced no-stop decompression tables.
The early Navy tables were designed for single dives only, as Gilliam points out. In 1957 Des Granges produced the Navy's repetitive air tables, using tissue half-times of 40, 80, 120 and 240 minutes, based on Dwyer's data.
M-values and the Swiss algorithm
Haldane's fixed 2 to 1 rule proved too cautious for the fast compartments. In 1965 Robert Workman introduced the idea of M-values: the maximum nitrogen tension a given compartment can tolerate at the surface without bubble formation. Each compartment gets its own limit, as large as 4 to 1 for the fastest, Swayne notes.
In Zurich, the lung physiologist Albert Bühlmann developed a multi-tissue algorithm that resembles the Workman formula. Wendling and colleagues record a 12-tissue model in 1972 and a table set built on 16 tissues in 1986, and say sports divers embraced the algorithm.
Listening for bubbles: Doppler ultrasound
Doppler ultrasound listens for bubbles in the blood.
Walker's review reports that the first unequivocal bubble signals in a person came in 1969, when Spencer placed an external sensor over the arm vein of a diver who had decompression illness in that arm. Walker notes that Doppler-detectable bubbles are found in virtually any decompression profile, and many people with them have no symptoms.
From tables to computers
PADI funded a new decompression model for no-stop diving in 1987, and introduced the Recreational Dive Planner, as a table and The Wheel, in 1988. PADI's own history describes these as the first dive tables created specifically for no-stop recreational diving.
Electronic computers arrived alongside. Huggins's 1981 tables became the basis of what Gilliam describes as the first practical electronic dive computer. In Zurich, Bühlmann was asked to help put his algorithm into the first computers. Wendling and colleagues say he had never dived, regarded recreational divers as foolhardy, and refused at first. He accepted once he recognised that divers would use computers anyway, so they might as well use his algorithm. Our article on what a dive computer algorithm changes looks at how they differ.
One vocabulary note: in the 1930s Behnke and the US Navy submarine escape unit recognised arterial gas embolism as a different disorder, and in 1990 a meeting at Alverstoke in the UK proposed decompression illness to cover both.
What this history means for a diver today
- Limits are models. As Walker's finding suggests, bubbles form even on routine profiles, so tables and computers are estimates built on experiments. Follow your instructor and your computer manual.
- Nitrox is one way to take up less nitrogen. Nitrox gives a longer no-stop time at a given depth and never lets you go deeper. For what it does and does not change about DCS risk, see our decompression sickness guide. Read why enriched air does not let you dive deeper, or see our Nitrox course. Dive planning basics are taught in the Open Water course.
- Waiting before a flight is its own question. See flying after diving.
Frequently asked questions
Is it caisson disease or Cason's disease?
It is caisson disease, from the French caisse, meaning box (Acott). A caisson is the pressurised chamber used for bridge and tunnel foundations. Cason's is a misspelling.
Are the bends and DCS the same thing?
Yes. DAN's glossary lists the bends as another name for decompression sickness. Divers and the public use the bends, while doctors and training agencies use DCS.
Who discovered decompression sickness?
No single person did. Robert Boyle described bubbles in a viper in 1670, Triger recorded the first two cases in French miners in 1841, and Paul Bert showed in 1878 that nitrogen bubbles were the cause.
What is DCI, and how is it different from DCS?
Decompression illness (DCI) is the broad term covering both decompression sickness (DCS) and arterial gas embolism (AGE). A 1990 meeting at Alverstoke in the UK proposed it. People often use the terms loosely.
How did the early Navy tables work?
The US Navy tables of 1915 were modified by French and Stillson. Acott and Gilliam describe them as a version of Haldane's tables for single dives only.
Do modern dive computers still use Haldane's ideas?
Bühlmann's algorithm went into some of the first computers (Wendling), and it builds on the compartment idea Haldane used. Check your own computer's manual for its algorithm.
Was it called the bends because of posture?
That is the explanation given in Chris Acott's 1999 history. During the Brooklyn Bridge project, caisson workers who were affected walked with a stoop like the fashionable Grecian bend, and doing the bend became the bends.
Who first detected bubbles in a diver's blood?
Walker's review reports that Spencer detected the first unequivocal bubble signals in 1969, using an external Doppler sensor placed over a vein in the arm of a diver with decompression illness.
Sources
- Acott C. A brief history of diving and decompression illness. SPUMS Journal 1999; 29(2): 98 to 107. Supports Boyle, Triger, the word caisson, the bridge figures, Smith, the bends, Bert, Hill and Greenwood, Haldane, the Navy tables, Behnke and the 1990 DCI term. Read the paper.
- Wendling J, Nussberger P, Schenk B. Milestones of the Deep Diving Research Laboratory Zurich. SPUMS Journal 1999; 29(2): 91 to 97. Supports Bühlmann's algorithm and his role in early computers. SPUMS Journal, June 1999 issue.
- Walker M. Doppler bubble detection after hyperbaric exposure. SPUMS Journal 1996; 26(3): 146 to 154. Supports the Doppler history. Read the paper.
- Swayne M. The contributions of J. S. Haldane to dive safety, Scientific American blog, 2012. Supports the goats, compartments and M-values. Read the post.
- Gilliam B. Historical perspectives on dive tables and decompression models, Undercurrent, 2012. Supports Workman and the early computer. Read the article.
- Smith AH. The effects of high atmospheric pressure, including the caisson disease. Brooklyn, 1873 (US National Library of Medicine copy, Internet Archive). Supports the book title and date. View the copy.
- PADI blog. PADI decades: the 1980s. Supports the 1987 funding and 1988 introduction of the Recreational Dive Planner. Read the post.
- DAN. Travelers Medical Guide glossary. Supports the definitions of DCS, DCI, AGE and the bends. Read the glossary.
Reviewed November 2026. Devon Ford, PADI IDC Staff Instructor, runs Scuba Evolution, a PADI 5 Star Dive Centre in Glenvista, Johannesburg.
This article is for general information and is not medical advice or a substitute for training. If you feel unwell after a dive, seek medical help straight away and call DAN Southern Africa on +27 82 810 6010.